High-Performance 60 AMP Solid State Relay for Industrial Use

Product Details
Customization: Available
Theory: Solid State Relay
Phase: Solid State Relay
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
Find Similar Products

Basic Info.

Model NO.
GAG6H-1/032F-60
Electricity Type
Solid State Relay
Number of Pole
Solid State Relay
Load
40-440VAC
Protective Characteristics
Enclosed Relay
Action Principle
Solid State Relay
Size
Miniature
Type
Solid State Relay
Model
Gag6h-1/032f-60
Controlling Voltage
4~32VDC
Make-on Voltage
4VDC
Break-off Voltage
2VDC
Indicate Methods
LED
Transport Package
Cartons
Specification
UL RoHS CCC CE TUV
Trademark
NCR
Origin
China
HS Code
85364110
Production Capacity
1000PCS/Per Day

Product Description

Product Name: 60Z Rail Solid State Relay (GAG6H-1/032F-60)

High-Performance 60 AMP Solid State Relay for Industrial Use
 
Model GAG6H-1/032F-60
Description Rail Soil State Relay
Controlling Voltage 032:4~32VDC
Controlling Current <20mA
Make-on Voltage 4VDC
Break-off Voltage 2VDC
Reverse Voltage -
Load Voltage 38:40-440VAC
Load Current 60,80A
Instant Voltage 38:900VAC
Voltage Dropin On <1.6VAC
On-off Time ≤10ms
Leakage Current in off ­≤10mA
Dielectric Strength ≥2500VAC
Insulation Resistance 500m uohm/500VDC
   
   




Remarks:
1. Ensure that the output power remains as AC Voltage for optimal performance.
2. Utilize a Potentiometer adjusted with 2W470-560K for precise modulation.
3. For SSRs handling loads above 10 Amps, mount them on a robust heat sink. For loads exceeding 80 Amps, consider advanced cooling solutions like fan-cooling or
water-cooling systems to ensure efficiency and longevity.

Features of the 60Z Rail Solid State Relay:
Experience the unmatched efficiency of no-contact relays, utilizing semiconductor technology for rapid, high-frequency operations.
Fully adheres to RoHS compliance, ensuring safety and environmental responsibility.
Models available cater to diverse needs, including options without zero cross.
Easily maintain your relay with replaceable power elements.
Designed in accordance with cULus and CE standards for international reliability and safety.

Understanding SSR (Solid State Relay):
Solid State Relays (SSRs) are electronic switching devices that turn power on or off to other devices, akin to a mechanical switch but activated electronically. They enable control over high-current devices-like lighting or appliances-using low-current signals, such as a standard DC signal emitted from a Digital Output. Most SSRs activate at a voltage of 3V or higher, making them ideal for integration with Phidget Interface Kits or any digital outputenabled device.
SSRs offer the same functionality as Mechanical Relays, with these outstanding benefits:
  • During operation, SSRs generate significantly less electromagnetic interference compared to mechanical relays. This reduction is largely due to the absence of contact arcing , a phenomenon unique to mechanical relays, where physical contacts spark internally. This minimized interference also stems from the SSR's non-reliance on electromagnets for switching functionality.
  • Mechanical relay contacts deteriorate over time due to arcing. Conversely, an SSR boasts a digitally-driven, frictionless operation, ensuring a longer lifespan, capable of millions of cycles.
  • SSRs excel in speed, switching on and off in just 1ms, significantly faster than the 10ms typical of mechanical relays.
  • SSRs maintain reliability even amidst physical vibrations, unlike their mechanical counterparts.
  • The absence of a mechanical switch in SSRs means they do not experience contact bounce , providing silent operations.

How SSRs Function:
Internally, control inputs connect to an LED, which emits light across an air gap to reach sensors. These sensors link to transistors that manage the relay's load power. When a transistor is closed, it allows current to flow seamlessly, connecting the load to the power source. Conversely, when a transistor is open, it blocks nearly all current, disconnecting the load from the power source. This LED-sensor pairing, known as an optocoupler, is a sophisticated method to connect circuit parts without a direct electrical link.

Why Choose NCR & Clion?
1. As renowned manufacturers, researchers, and exporters of electronic components, we bring extensive expertise to the table.
2. With 14 years of experience in producing relays and a wide variety of electronics, our expertise is your advantage.
3. Operating under the esteemed ISO 9001 & ISO 14000 quality control framework, we commit to unparalleled production standards.;
4. Our comprehensive sales service system guarantees that every aspect of your experience with us is as seamless as possible.
5. Our innovative R&D Department unveils a captivating array of newly designed products annually, keeping us at the forefront of industry advancement.
6. With our impeccable testing system, we ensure that each product meets the highest standards of quality and reliability.
7. Eager to discover more about us? We warmly welcome your inquiries and are excited to engage with you.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier